Transcatheter aortic valve replacement in membranous interventricular septum aneurysm with left ventricular outflow tract extension
We report a challenging case of a 81-year-old male with history of severe calcific aortic valve stenosis and aneurysmal membranous interventricular septum. The presence of anomalies in the sub-annular area can lead to valve malpositioning and its consequences. transcatheter aortic valve implantation...