Fetal cardiac cine imaging using highly accelerated dynamic MRI with retrospective motion correction and outlier rejection

PURPOSE: Development of a MRI acquisition and reconstruction strategy to depict fetal cardiac anatomy in the presence of maternal and fetal motion. METHODS: The proposed strategy involves i) acquisition and reconstruction of highly accelerated dynamic MRI, followed by image‐based ii) cardiac synchro...