Technical note: The effect of the 4‐mm‐collimator output factor on gamma knife dose distributions

We present results of investigations of the clinical significance of variations in the value of the 4‐mm‐collimator output factor, [Formula: see text]. Changes in treatment volume, dose‐volume histograms (DVHs), and isodose distributions were studied, by varying [Formula: see text] up to 20%. The va...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:J Appl Clin Med Phys
Main Authors: Gibbons, John P., Mihailidis, Dimitris, Worthington, Curtis, Alkhatib, Hassaan, Boulware, Raleigh, Clark, Robert, Dial, Burke, Neglia, William
Formato: Artigo
Idioma:Inglês
Publicado em: John Wiley and Sons Inc. 2003
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC5724451/
https://ncbi.nlm.nih.gov/pubmed/14604431
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1120/jacmp.v4i4.2512