Reducing oral contamination during corneal scrapes

AIMS: To identify potential contaminants of the corneal sampling procedure and examine the effect of wearing surgical face masks on the rate of contamination. METHODS: Ten surgeons recited out loud a 30 s standardised script for corneal scraping with blood agar plates positioned 30 cm away from them...