Commissioning compensator‐based IMRT on the Pinnacle treatment planning system

We present a systematic approach to commissioning of the compensator‐based IMRT in Pinnacle treatment planning system for commercially manufactured brass compensators. Some model parameters for the beams modulated by the variable‐thickness compensators can only be associated with a single compensato...