Wird geladen...

Individualized margins for prostate patients using a wireless localization and tracking system

This study investigates the dosimetric benefits of designing patient‐specific margins for prostate cancer patients based on 4D localization and tracking. Ten prostate patients, each implanted with three radiofrequency transponders, were localized and tracked for 40 fractions. “Conventional margin” (...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:J Appl Clin Med Phys
Hauptverfasser: Rassiah‐Szegedi, Prema, Wang, Brian, Szegedi, Martin, Tward, Jonathan, Zhao, Hui, Huang, Y. Jessica, Sarkar, Vikren, Shrieve, Dennis, Salter, Bill
Format: Artigo
Sprache:Inglês
Veröffentlicht: John Wiley and Sons Inc. 2011
Schlagworte:
Online Zugang:https://ncbi.nlm.nih.gov/pmc/articles/PMC5718642/
https://ncbi.nlm.nih.gov/pubmed/21844865
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1120/jacmp.v12i3.3516
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!