Individualized margins for prostate patients using a wireless localization and tracking system
This study investigates the dosimetric benefits of designing patient‐specific margins for prostate cancer patients based on 4D localization and tracking. Ten prostate patients, each implanted with three radiofrequency transponders, were localized and tracked for 40 fractions. “Conventional margin” (...