Biosynthetic graft failure to replace infected infrainguinal bypass as developing infection due to Morganella morganii leading to disrupture of the anastomosis. Case report

INTRODUCTION: Biosynthetic prosthesis has become the trend to carry out arterial reconstruction in infected sites since considered to be resistant to infection. Late graft occlusion is the only complication reported in literature so far. We report a case of biosynthetic graft infection which led to...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Pubblicato in:Int J Surg Case Rep
Autori principali: Zenunaj, Gladiol, Spataro, Claudio, Traina, Luca, Gasbarro, Vincenzo
Natura: Artigo
Lingua:Inglês
Pubblicazione: Elsevier 2017
Soggetti:
Accesso online:https://ncbi.nlm.nih.gov/pmc/articles/PMC5699879/
https://ncbi.nlm.nih.gov/pubmed/29546004
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.ijscr.2017.11.010