Wird geladen...

Method to remove photoreceptors from whole mount retina in vitro

Patch clamp recordings of neurons in the inner nuclear layer of the retina are difficult to conduct in a whole mount retina preparation because surrounding neurons block the path of the patch pipette. Vertical slice preparations or dissociated retinal cells provide access to bipolar cells at the cos...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:J Neurophysiol
Hauptverfasser: Walston, Steven T., Chang, Yao-Chuan, Weiland, James D., Chow, Robert H.
Format: Artigo