Refrigerant Performance Evaluation Including Effects of Transport Properties and Optimized Heat Exchangers

Preliminary refrigerant screenings typically rely on using cycle simulation models involving thermodynamic properties alone. This approach has two shortcomings. First, it neglects transport properties, whose influence on system performance is particularly strong through their impact on the performan...

Descripció completa

Guardat en:
Dades bibliogràfiques
Publicat a:Int J Refrig
Autors principals: Brignoli, Riccardo, Brown, J. Steven, Skye, H., Domanski, Piotr. A.
Format: Artigo
Idioma:Inglês
Publicat: 2017
Matèries:
Accés en línia:https://ncbi.nlm.nih.gov/pmc/articles/PMC5600208/
https://ncbi.nlm.nih.gov/pubmed/28924306
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.ijrefrig.2017.05.014
Etiquetes: Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!