Carbon dioxide narcosis due to inappropriate oxygen delivery: a case report

BACKGROUND: Oxygen delivery to patients with chronic obstructive pulmonary disease may be challenging because of their potential hypoxic ventilatory drive. However, some oxygen delivery systems such as non-rebreathing face masks with an oxygen reservoir bag require high oxygen flow for adequate oxyg...