Dynamic Fixation of Humeral Shaft Fractures Using Active Locking Plates: A Prospective Observational Study

BACKGROUND: Rigid locked plating constructs can suppress fracture healing by inhibiting interfragmentary motion required to stimulate natural bone healing by callus formation. Dynamic fixation with active locking plates reduces construct stiffness, enables controlled interfragmentary motion, and has...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:Iowa Orthop J
Main Authors: Madey, Steven M., Tsai, Stanley, Fitzpatrick, Daniel C., Earley, Kathleen, Lutsch, Michael, Bottlang, Michael