Third CoreValve™ insertion for treatment of a severe paravalvular leak after a failed valve-in-valve procedure

An 83-year-old high-risk gentleman diagnosed with severe symptomatic aortic stenosis was scheduled for TAVR. A 31 mm CoreValve was implanted but severe paravalvular leak was noted. A valve-in-valve procedure was performed. However, the valve frame was partially dislodged into de ascending aorta. We...