Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

OBJECTIVES: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. MATERIALS AND METHODS: An in vitro experiment was con...

Descrición completa

Gardado en:
Detalles Bibliográficos
Publicado en:J Korean Assoc Oral Maxillofac Surg
Main Authors: Vieira Santos, Zarina Tatia Barbosa, Goulart, Douglas Rangel, Sigua-Rodriguez, Eder Alberto, Pozzer, Leandro, Olate, Sergio, Albergaria-Barbosa, José Ricardo
Formato: Artigo
Idioma:Inglês
Publicado: The Korean Association of Oral and Maxillofacial Surgeons 2017
Assuntos:
Acceso en liña:https://ncbi.nlm.nih.gov/pmc/articles/PMC5410431/
https://ncbi.nlm.nih.gov/pubmed/28462190
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.5125/jkaoms.2017.43.2.77