The resistance of collateral channels in excised human lungs

We measured the resistance of collateral channels, R(col), in incomplete interlobar fissures in eight normal and eight emphysematous excised human lungs. Similar measurements were also made from the basal segments to the superior segment of the lower lobe in three normal and five emphysematous lungs...