Cargando...

Bradycardia during Transradial Cardiac Catheterization due to Catheter Manipulation: Resolved by Catheter Removal

Purpose. To report the resolution of bradycardia encountered during transradial cardiac catheterization through the catheter pullback technique in two cases. Case Report. A 62-year-old male and an 81-year-old male underwent coronary angiogram to evaluate for coronary artery disease and as a result o...

Descrición completa

Gardado en:
Detalles Bibliográficos
Publicado en:Case Rep Vasc Med
Main Authors: Gedela, Maheedhar, Kumar, Vishesh, Shaikh, Kashif Abbas, Stys, Adam, Stys, Tomasz
Formato: Artigo
Idioma:Inglês
Publicado: Hindawi 2017
Assuntos:
Acceso en liña:https://ncbi.nlm.nih.gov/pmc/articles/PMC5350482/
https://ncbi.nlm.nih.gov/pubmed/28348915
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1155/2017/8538149
Tags: Engadir etiqueta
Sen Etiquetas, Sexa o primeiro en etiquetar este rexistro!