Comparison of the cuff pressure of a TaperGuard endotracheal tube and a cylindrical endotracheal tube after lateral rotation of head during middle ear surgery: A single-blind, randomized clinical consort study
BACKGROUND: Positional change affects the cuff pressure of an endotracheal tube (ETT) in treacheally intubated patients. We compared the cuff pressure of a TaperGuard ETT and a cylindrical ETT after lateral rotation of head during middle ear surgery. METHODS: Fifty-two patients aged 18–70 years unde...