Loading...

Comparison of 2 mm single locking miniplates versus 2 mm two non-locking miniplates in symphysis and parasymphysis fracture of mandible

INTRODUCTION: The purpose of this study is to compare the efficacy of single 2 mm locking miniplates versus two 2 mm non-locking (conventional) miniplates in symphysis and parasymphysis fracture of mandible. METHOD: This present study included 40 patients of maxillofacial trauma having mandibular sy...

Full description

Saved in:
Bibliographic Details
Published in:J Oral Biol Craniofac Res
Main Authors: Vashistha, Arpit, Singh, Manpreet, Chaudhary, Manoj, Agarwal, Nimish, Kaur, Gagandeep
Format: Artigo
Language:Inglês
Published: Elsevier 2017
Subjects:
Online Access:https://ncbi.nlm.nih.gov/pmc/articles/PMC5343153/
https://ncbi.nlm.nih.gov/pubmed/28316921
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.jobcr.2016.01.001