Cargando...

Evaluation of the agreement of tidal breathing parameters measured simultaneously using pneumotachography and structured light plethysmography

Structured light plethysmography (SLP) is a noncontact, noninvasive, respiratory measurement technique, which uses a structured pattern of light and two cameras to track displacement of the thoraco–abdominal wall during tidal breathing. The primary objective of this study was to examine agreement be...

Descrición completa

Gardado en:
Detalles Bibliográficos
Publicado en:Physiol Rep
Main Authors: Motamedi‐Fakhr, Shayan, Iles, Richard, Barney, Anna, de Boer, Willem, Conlon, Jenny, Khalid, Amna, Wilson, Rachel C.
Formato: Artigo
Idioma:Inglês
Publicado: John Wiley and Sons Inc. 2017
Assuntos:
Acceso en liña:https://ncbi.nlm.nih.gov/pmc/articles/PMC5309576/
https://ncbi.nlm.nih.gov/pubmed/28193785
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.14814/phy2.13124
Tags: Engadir etiqueta
Sen Etiquetas, Sexa o primeiro en etiquetar este rexistro!