A carregar...

An automatic, intercapillary area based algorithm for quantifying diabetes related capillary dropout using OCT angiography

PURPOSE: To develop a robust, sensitive, and fully automatic algorithm to quantify diabetes related capillary dropout using optical coherence tomography (OCT) angiography (OCTA). METHODS: A 1050 nm wavelength, 400 kHz A-scan rate swept-source OCT prototype was used to perform volumetric OCTA imaging...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:Retina
Main Authors: Schottenhamml, Julia, Moult, Eric M., Ploner, Stefan, Lee, ByungKun, Novais, Eduardo A., Cole, Emily, Dang, Sabin, Lu, Chen D., Husvogt, Lennart, Waheed, Nadia K., Duker, Jay S., Hornegger, Joachim, Fujimoto, James G.
Formato: Artigo
Idioma:Inglês
Publicado em: 2016
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC5193238/
https://ncbi.nlm.nih.gov/pubmed/28005667
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1097/IAE.0000000000001288
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!