Načítá se...

Inverse 4D conformal planning for lung SBRT using particle swarm optimization

A critical aspect of highly potent regimens such as lung stereotactic body radiation therapy (SBRT) is to avoid collateral toxicity while achieving planning target volume (PTV) coverage. In this work, we describe four dimensional conformal radiotherapy (4D CRT) using a highly parallelizable swarm in...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Phys Med Biol
Hlavní autoři: Modiri, A, Gu, X, Hagan, A, Bland, R, Iyengar, P, Timmerman, R, Sawant, A