Concurrent Angioplasty Balloon Placement for Stent Delivery through Jugular Venous Bulb for Treating Cerebral Venous Sinus Stenosis. Technical Report
OBJECTIVE: To report upon technique of concurrent placement of angioplasty balloon at the internal jugular vein and sigmoid venous sinus junction to facilitate stent delivery in two patients in whom stent delivery past the jugular bulb was not possible. CLINICAL PRESENTATION: A 21-year-old woman and...