Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics

BACKGROUND: Graft reperfusion poses a critical challenge during liver transplantation and can be associated with hemodynamic instability/postreperfusion syndrome. This is sequel to ischemia-reperfusion injury and normothermic machine preservation (NMP) may affect hemodynamic changes. Herein, we char...

Полное описание

Сохранить в:
Библиографические подробности
Опубликовано в: :Transplant Direct
Главные авторы: Angelico, Roberta, Perera, M. Thamara P. R, Ravikumar, Reena, Holroyd, David, Coussios, Constantin, Mergental, Hynek, Isaac, John R., Iqbal, Asim, Cilliers, Hentie, Muiesan, Paolo, Friend, Peter J., Mirza, Darius F.
Формат: Artigo
Язык:Inglês
Опубликовано: Lippincott Williams & Wilkins 2016
Предметы:
Online-ссылка:https://ncbi.nlm.nih.gov/pmc/articles/PMC5068202/
https://ncbi.nlm.nih.gov/pubmed/27795989
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1097/TXD.0000000000000611