Efficacy of Repeat Review with Flexible Spectral Imaging Color Enhancement in Patients with no Findings by Capsule Endoscopy
BACKGROUND/AIM: The efficacy of flexible spectral imaging color enhancement (FICE) ch. 1 (F1) for the detection of ulcerative lesions and angioectasias in the small intestine with capsule endoscopy (CE) has been reported. In the present study, we evaluated whether F1 could detect incremental finding...