Improvement of Contrast Media Enhancement in CTA Evaluating Pulmonary Embolism by Utilizing ‘Delayed’ Bolus Tracking in the Descending Aorta

BACKGROUND: As standard bolus triggering in the pulmonary trunk sometimes fails to achieve sufficient enhancement in the pulmonary arteries, the study investigates an alternative, ‘delayed’ position of the tracking ROI in the descending aorta. MATERIAL/METHODS: Retrospective analysis of 143 patients...