Comparative evaluation of the tensile bond strength of two silicone based denture liners with denture base resins

BACKGROUND: To evaluate and compare tensile bond strength of two silicone based liners with heat cure and heat cure high impact denture base resin at baseline and after storage in artificial saliva for 30 and 60 days. METHOD: Heat cure conventional and high impact acrylic blocks (120 blocks each) pr...

Täydet tiedot

Tallennettuna:
Bibliografiset tiedot
Julkaisussa:Med J Armed Forces India
Päätekijät: Mittal, Manish, Anil Kumar, S., Sandhu, H.S., Iyer, Satish R., Ahuja, Ratandeep S.
Aineistotyyppi: Artigo