Haemorrhagic colitis and haemolytic-uraemic syndrome: false positive reaction with a rotavirus latex agglutination test.

A stool sample from a child with haemorrhagic colitis and haemolytic-uraemic syndrome gave a positive reaction with the RotaScreen latex agglutination test in the absence of other evidence of rotavirus infection. When this test is performed on bloody specimens, positive reactions should be interpret...