OBJECTIVE: To determine the midpoint (MD) of extensor hallucis longus muscle (EHL) and compare the accuracy of different needle electromyography (EMG) insertion techniques through cadaver dissection. METHODS: Thirty-eight limbs of 19 cadavers were dissected. The MD of EHL was marked at the middle of...