Reverse Flipping Technique: An Alternate Approach to Tie Reversing Half-Hitches on Alternating Posts
Arthroscopic knot tying requires practice and attention to detail, especially tying the 3 reversing half-hitches on alternating posts (RHAPs) in a knot. Mistakes can occur that result in an unintentional tension (>10 N) applied to the wrapping suture limb, and by placing tension in the wrong limb...