The visible and hidden blood loss of Asia proximal femoral nail anti-rotation and dynamic hip screw in the treatment of intertrochanteric fractures of elderly high- risk patients: a retrospective comparative study with a minimum 3 years of follow-up
BACKGROUND: The purpose of this study was to evaluate whether PFNA-II (Asia proximal femoral nail anti-rotation) and DHS (dynamic hip screw) carry substantial post-operative hidden blood loss and to compare PFNA-II with DHS in terms of post-operative hidden blood loss in elderly high-risk patients w...