Increased plasma levels of lead in patients with amyotrophic lateral sclerosis compared with control subjects as determined by flameless atomic absorption spectrophotometry.

The levels of lead in plasma were determined in 16 cases of amyotrophic lateral sclerosis (ALS) and 18 control subjects, using flameless atomic absorption spectrophotometry. The mean values were 0.52+/-0.22 microgram/100ml (ALS) and 0.37+/-0.13 microgram/100ml (controls), the difference is statistic...

Description complète

Enregistré dans:
Détails bibliographiques
Auteurs principaux: Conradi, S, Ronnevi, L O, Vesterberg, O
Format: Artigo
Langue:Inglês
Publié: 1978
Sujets:
Accès en ligne:https://ncbi.nlm.nih.gov/pmc/articles/PMC493043/
https://ncbi.nlm.nih.gov/pubmed/77896