Cerebrospinal fluid pulse pressure and intracranial volume-pressure relationships.

In six anaesthetised and ventilated dogs the CSF pulse pressure was compared with the volume-pressure response (VPR) during continuous inflation of an extradural balloon. Both pulse pressure and VPR increased linearly with the ventricular fluid pressure (VFP) up to a mean VFP of 60 mmHg. At this pre...