Extension of the NIST AC-DC Difference Calibration Service for Current to 100 kHz
The NIST calibration service for ac-dc difference of thermal current converters relies on multijunction thermal converters as the primary standards, and various thermal converters and thermoelements (TEs) as the reference and working standards. Calibrations are performed by comparing the ac-dc diffe...