Thermal-Conductivity Apparatus for Steady-State, Comparative Measurement of Ceramic Coatings

An apparatus has been developed to measure the thermal conductivity of ceramic coatings. Since the method uses an infrared microscope for temperature measurement, coatings as thin as 20 μm can, in principle, be measured using this technique. This steady-state, comparative measurement method uses the...