Llwytho...

Thermal-Conductivity Apparatus for Steady-State, Comparative Measurement of Ceramic Coatings

An apparatus has been developed to measure the thermal conductivity of ceramic coatings. Since the method uses an infrared microscope for temperature measurement, coatings as thin as 20 μm can, in principle, be measured using this technique. This steady-state, comparative measurement method uses the...

Disgrifiad llawn

Wedi'i Gadw mewn:
Manylion Llyfryddiaeth
Cyhoeddwyd yn:J Res Natl Inst Stand Technol
Prif Awdur: Slifka, A. J.
Fformat: Artigo
Iaith:Inglês
Cyhoeddwyd: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2000
Pynciau:
Mynediad Ar-lein:https://ncbi.nlm.nih.gov/pmc/articles/PMC4877160/
https://ncbi.nlm.nih.gov/pubmed/27551628
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.6028/jres.105.050
Tagiau: Ychwanegu Tag
Dim Tagiau, Byddwch y cyntaf i dagio'r cofnod hwn!