Systemic air embolism causing acute stroke and myocardial infarction after percutaneous transthoracic lung biopsy – a case report

The air embolism in this case was likely to have been caused by positioning the patient in a prone position, which was associated with the lesion to be biopsied being at a maximum height over the left atrium. Due to the resulting negative pressure, air entered through a fistula that formed between t...