Codice QR

Measurement of stroke volume from pulmonary artery pressure record in man.

Stroke volume was determined from the pulmonary artery pressure record by application of the pulse contour method. Pulmonary artery pressure records were obtained in 17 patients using a high fidelity catheter-tip pressure transducer and simultaneous measurements of cardiac output were obtained from...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Pubblicato in:Br Heart J
Autori principali: Zacharoulis, A A, Evans, T R, Ziady, G M, Coltart, D J, Shillingford, J P
Natura: Artigo
Lingua:Inglês
Pubblicazione: BMJ Publishing Group 1975
Soggetti:
Accesso online:https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC484150/
https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/803378/
https://ncbi.nlm.nih.govhttps://doi.org/10.1136/hrt.37.1.20
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!