Mechanical behavior of deep cryogenically treated martensitic shape memory nickel–titanium rotary endodontic instruments

OBJECTIVES: The aim of this study was to investigate the role of deep cryogenic treatment (DCT) on the cyclic fatigue resistance and cutting efficiency of martensitic shape memory (SM) nickel–titanium (NiTi) rotary endodontic instruments. MATERIALS AND METHODS: Seventy-five HyFlex(®) CM instruments...