Vapor intrusion attenuation factors relative to subslab and source, reconsidered in light of background data

The basis upon which recommended attenuation factors for vapor intrusion (VI) have been derived are reconsidered. By making a fitting curve to the plot showing the dependence of observed indoor air concentration (c(in)) on subslab concentration (c(ss)) for residences in EPA database, an analytical e...