Assay of rifampicin in serum

Two methods for the assay of rifampicin in serum are described. The first is a conventional plate diffusion method, measuring concentrations down to 0·02 μg/ml, and the second a chemical extraction followed by measurement of the inhibition of uptake of (14)C-uridine by Staphylococcus aureus, which e...