Routine application of the nitroblue tetrazolium test in the clinical laboratory

A modified nitroblue tetrazolium test (NBT) is described which is suitable for routine application in the haematology or bacteriology laboratory and which provides a rapid aid to the diagnosis of bacterial infection. Hitherto published methods have recommended the use of heparinized whole blood samp...