Laboratory control of heparin therapy

The effect of heparin therapy was followed in 50 patients treated for thrombo-embolic disease. Individual response to a standard dose of 40,000 units of heparin daily showed a considerable variation and the effect was not constant on subsequent days. Five of the 50 patients developed a serious haemo...