Caricamento...
Factor V Leiden and Cardiopulmonary Bypass
We present a case of a patient with factor V Leiden with an antithrombin III activity of 67% who received a successful aortic valve replacement supported by cardiopulmonary bypass (CPB). A safe level of anticoagulation was achieved by monitoring activated clotting time (ACT) and heparin concentratio...
Salvato in:
| Pubblicato in: | J Extra Corpor Technol |
|---|---|
| Autori principali: | , , , , , |
| Natura: | Artigo |
| Lingua: | Inglês |
| Pubblicazione: |
American Society of ExtraCorporeal Technology
2015
|
| Soggetti: | |
| Accesso online: | https://ncbi.nlm.nih.gov/pmc/articles/PMC4730165/ https://ncbi.nlm.nih.gov/pubmed/26834284 |