QR Kod

Occupational asthma in a factory making flux-cored solder containing colophony.

The prevalence of work-related wheeze and breathlessness was measured in factory employees manufacturing flux-cored solder. The flux contained colophony which was heated in the production process, exposing the workers to colophony fumes. Measurement of colophony in the breathing zone defined three g...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Yayımlandı:Thorax
Asıl Yazarlar: Burge, P S, Edge, G, Hawkins, R, White, V, Taylor, A J
Materyal Türü: Artigo
Dil:Inglês
Baskı/Yayın Bilgisi: BMJ Publishing Group 1981
Konular:
Online Erişim:https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC471823/
https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/7330804/
https://ncbi.nlm.nih.govhttps://doi.org/10.1136/thx.36.11.828
Etiketler: Etiketle