An annual cycle in the ventilatory capacity of men with pneumoconiosis and of normal subjects
The forced expiratory volume over 0·75 second (F.E.V.(0·75)) was measured monthly for 3 years in 28 working ex-miners with pneumoconiosis and for one year in 17 normal laboratory workers. A significant annual cyclical variation of 0·044 litre amplitude was found in the ex-miners, with minimum and ma...