A carregar...

Hypersensitivity pneumonitis in a technician using Pauli's reagent.

A technician working in a medical laboratory used a spray of sodium diazobenzenesulphate (Pauli's reagent) in chromatography. She developed a respiratory illness with both airways obstruction and radiographic and physiological evidence of interstitial pneumonitis. An occupational type of challe...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Evans, W V, Seaton, A
Formato: Artigo
Idioma:Inglês
Publicado em: 1979
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC471194/
https://ncbi.nlm.nih.gov/pubmed/542917