Código QR (código de barras bidimensional)

Mitral valve replacement with stored inverted pulmonary homograft valve

The fate is described of 11 patients who had a stored pulmonary valve homograft mounted on a frame or in a Dacron jacket used for mitral valve replacement. Mitral regurgitation due to holes in the attenuated cusps occurred in nine by one year, requiring re-operation or causing death. Only one patien...

Fuld beskrivelse

Na minha lista:
Bibliografiske detaljer
Udgivet i:Thorax
Principais autores: Somerville, Jane, Ross, Donald, Ross, J. Keith
Format: Artigo
Sprog:Inglês
Udgivet: BMJ Publishing Group 1972
Fag:
Online adgang:https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC470557/
https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/5083726/
https://ncbi.nlm.nih.govhttps://doi.org/10.1136/thx.27.5.583
Tags: Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!