A complication of percutaneous cannulation of the internal jugular vein
Reviews of the use of the technique of percutaneous cannulation of the internal jugular vein for central venous pressure monitoring have indicated that it is free from serious complications. A patient is reported here in whom the ascending cervical artery was damaged during attempted cannulation of...