The role of aortic compliance in determination of coarctation severity: lumped parameter modeling, in vitro study and clinical evaluation

Early detection and accurate estimation of the extent of coarctation of the aorta (COA) is critical to long-term outcome. Peak-to-peak trans-coarctation pressure gradient (P(K)dP) higher than 20 mmHg is an indication for interventional/surgical repair. Patients with COA have reduced proximal and dis...

Descripción completa

Guardado en:
Detalles Bibliográficos
Publicado en:J Biomech
Autores principales: Keshavarz-Motamed, Zahra, Edelman, Elazer R., Motamed, Payam K., Garcia, Julio, Dahdah, Nagib, Kadem, Lyes