Percutaneous Antegrade Removal of Encrusted Broken Double J Ureteric Stent Using a Snare

Percutaneous removal of partially encrusted broken double J ureteric stent from the renal pelvis using a snare is described. The patient is a 60-year old female, with a known case of hyperparathyroidism with double J ureteric stent placed one year earlier. Removal of the double J stent was attempted...