Pleural effusion caused by a malpositioned umbilical venous catheter in a neonate

Umbilical venous catheterisation (UVC) insertion is a common procedure performed in most neonatal units. We report a case of a neonate who developed pleural and pericardial effusions and ascites due to a malpositioned UVC causing diaphragmatic perforation. Timely diagnosis using bedside sonography a...