Yüklüyor......
The impact of air pockets around the vaginal cylinder on vaginal vault brachytherapy
OBJECTIVE: To evaluate the incidence, size and predisposing factors for air pockets around the vaginal cylinder and their dosimetric effect on the vaginal mucosa. METHODS: We investigated 174 patients with endometrial carcinoma treated with external radiotherapy (RT) and brachytherapy (BRT) (101 pat...
Kaydedildi:
| Yayımlandı: | Br J Radiol |
|---|---|
| Asıl Yazarlar: | , , |
| Materyal Türü: | Artigo |
| Dil: | Inglês |
| Baskı/Yayın Bilgisi: |
The British Institute of Radiology.
2015
|
| Konular: | |
| Online Erişim: | https://ncbi.nlm.nih.gov/pmc/articles/PMC4651195/ https://ncbi.nlm.nih.gov/pubmed/25562767 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1259/bjr.20140694 |
| Etiketler: |
Etiketle
Etiket eklenmemiş, İlk siz ekleyin!
|